2024-08-26 14:30:28
Click:
OIL SERIES PULSE TEST BENCH-TIANJIN GETES TESTING EQUIPMENT TECHNOLOGY DEVELOPMENT CO., LTD.

It is mainly developed as a impulse test bench for power steering pipes, brake pipes, air conditioning pipes, fuel pipes, condensers, evaporators, oil coolers, steel pipes, Bondi pipes, etc., using hydraulic oil, ATF oil, mineral oil, brake fluid, and fuel as circulating media. It integrates multiple functions such as high and low frequency control, multiple waveforms, medium temperature, and environmental temperature into a comprehensive performance test bench.
Main functions and features:
1. The equipment adopts electro-hydraulic servo control mode, advanced international technology, stable system, and no welding in the pipeline.
2. The main components of the equipment are all imported parts, ensuring safe and reliable operation.
3. The equipment adopts the dedicated control testing software developed by LABVIEW, which completes the fully automatic control, automatic measurement, and automatic start protection functions of the test process. It displays and records the set parameters such as pressure, temperature, pulse waveform in real time, and is suitable for unmanned surveillance aircraft.
4. The internal structure of the equipment is reasonable and the layout is beautiful. Adopting non welded pipeline connection to prevent leakage and facilitate maintenance;
5. Different fixtures and jigs are suitable for connecting different products.
Selection range of equipment technical parameters:
Scope of application
Power steering pipe, brake pipe, air conditioning pipe, fuel pipe, condenser, evaporator, oil cooler, steel pipe, Bondi pipe, etc
Applicable standards
TL82415, SAEJ188, GB/T16897, GB/T20461, SAEJ191, ISO6803, GB/T5568, QC/T664, GMW14319, TL82253, GB/T20025, SAEJ1681, GMW8150, SAEJ517, etc
Pressure optional range
0-100MPa can be freely selected
Optional range of pulse frequency
0-5Hz can be freely selected
Test frequency setting range
0-10 million times
Optional range of ambient temperature
-50-200 ℃ can be freely selected, control mode: temperature 'fixed value control' and 'alternating control' can be selected
Optional range of medium temperature
-50-200 ℃ can be freely selected
Optional range of test media
Hydraulic oil, ATF oil, mineral oil, brake fluid, fuel, etc
Optional range of vibration modes
Electromagnetic vibration (including sweep frequency and vertical vibration), mechanical vertical vibration, servo vibration, mechanical rotational vibration
Installation method
Hose connection, 90 °, 180 ° connection
Number of experimental products
Route 2-10